Nombre de documents

19


Article dans une revue14 documents

  • Vladeta Zmijanovic, Simon Mendez, Vincent Moureau, Franck Nicoud. About the Numerical Robustness of Biomedical Benchmark Cases: Interlaboratory FDA's Idealized Medical Device. International Journal for Numerical Methods in Biomedical Engineering, John Wiley and Sons, 2016, <10.1002/cnm.2789>. <hal-01290017>
  • J Sigüenza, Simon Mendez, Dominique Ambard, Frédéric Dubois, Franck Jourdan, et al.. Validation of an immersed thick boundary method for simulating fluid–structure interactions of deformable membranes. Journal of Computational Physics, Elsevier, 2016, 322, pp.723-746. <10.1016/j.jcp.2016.06.041>. <hal-01348721>
  • Luca Lanotte, Johannes Mauer, Simon Mendez, Dmitry Fedosov, Jean-Marc Fromental, et al.. Red cells’ dynamic morphologies govern blood shear thinning under microcirculatory flow conditions. Proceedings of the National Academy of Sciences of the United States of America , National Academy of Sciences, 2016, <10.1073/pnas.1608074113>. <hal-01396939>
  • Christophe Chnafa, Simon Mendez, Franck Nicoud. Image-Based Simulations Show Important Flow Fluctuations in a Normal Left Ventricle: What Could be the Implications?. Annals of Biomedical Engineering, Springer Verlag, 2016, <http://link.springer.com/article/10.1007/s10439-016-1614-6>. <10.1007/s10439-016-1614-6>. <hal-01303067>
  • Etienne Loiseau, Gladys Massiera, Simon Mendez, Patricia Aguilar-Martinez, Manouk Abkarian. Microfluidic Study of Enhanced Deposition of Sickle Cells at Acute Corners. Biophysical Journal, Biophysical Society, 2015, 108 (11), pp.2623-2632. <10.1016/j.bpj.2015.04.018>. <hal-01164311>
  • Mathieu Sanchez, Omer Ecker, Dominique Ambard, Franck Jourdan, Franck Nicoud, et al.. Intracranial aneurismal pulsatility as a new individual criterion for rupture risk evaluation: Biomechanical and numerical approach (IRRAs project).. American Journal of Neuroradiology, American Society of Neuroradiology, 2014, 35 (9), pp.1765-1771. <10.3174/ajnr.A3949>. <hal-00910141>
  • Simon Mendez, Etienne Gibaud, Franck Nicoud. An unstructured solver for simulations of deformable particles in flows at arbitrary Reynolds numbers. Journal of Computational Physics, Elsevier, 2014, 256 (1), pp.465-483. <10.1016/j.jcp.2013.08.061>. <hal-00871557>
  • Christophe Chnafa, Simon Mendez, Franck Nicoud. Image-based large-eddy simulation in a realistic left heart. Computers and Fluids, Elsevier, 2014, 94, pp.173-187. <10.1016/j.compfluid.2014.01.030>. <hal-00943609>
  • Marco Martins Afonso, Simon Mendez, Franck Nicoud. On the damped oscillations of an elastic quasi-circular membrane in a two-dimensional incompressible fluid. Journal of Fluid Mechanics, Cambridge University Press (CUP), 2014, 746, pp.300 -331. <10.1017/jfm.2014.135>. <hal-00957710>
  • Mathieu Sanchez, Dominique Ambard, Vincent Costalat, Simon Mendez, Franck Jourdan, et al.. Biomechanical Assessment of the Individual Risk of Rupture of Cerebral Aneurysms: A Proof of Concept. Annals of Biomedical Engineering, Springer Verlag, 2012, 41 (1), pp.28-40. <10.1007/s10439-012-0632-2>. <hal-00737354>
  • Elsa Gullaud, Simon Mendez, Claude Sensiau, Franck Nicoud, Thierry Poinsot. Effect of multiperforated plates on the acoustic modes in combustors. Comptes rendus de l’Académie des sciences. Série IIb, Mécanique, Elsevier, 2009, 337 (6-7), pp.406-414. <10.1016/j.crme.2009.06.020>. <hal-00803809>
  • Florent Duchaine, Simon Mendez, Franck Nicoud, Alban Corpron, Vincent Moureau, et al.. Conjugate heat transfer with Large Eddy Simulation for gas turbine components. Comptes rendus de l’Académie des sciences. Série IIb, Mécanique, Elsevier, 2009, 337 (6-7), pp.550-561. <10.1016/j.crme.2009.06.005>. <hal-00803816>
  • Simon Mendez, Franck Nicoud. Adiabatic Homogeneous Model for Flow Around a Multiperforated Plate. AIAA Journal, American Institute of Aeronautics and Astronautics, 2008, 46 (10), pp.2623-2633. <10.2514/1.37008>. <hal-00820458>
  • Simon Mendez, Franck Nicoud. Large-eddy simulation of a bi-periodic turbulent flow with effusion. Journal of Fluid Mechanics, Cambridge University Press (CUP), 2008, 598, pp.27-65. <10.1017/S0022112007009664>. <hal-00820464>

Communication dans un congrès3 documents

  • Franck Jourdan, Mathieu Sanchez, Dominique Ambard, Simon Mendez, Franck Nicoud, et al.. Inverse Mechanical analysis for cerebral aneurism risk rupture assessment. 7th World Congress of Biomechanics, Jul 2014, Boston, United States. <hal-01092037>
  • Etienne Gibaud, Julien Siguenza, Simon Mendez, Franck Nicoud. Towards numerical prediction of red blood cells dynamics within a cytometer. 38th Congress of the Societe-de-Biomecanique, 2013, Marseille, France. 16 (1), pp.9-10, 2013, <10.1080/10255842.2013.815883>. <hal-00862700>
  • Christophe Chnafa, Simon Mendez, Franck Nicoud, Ramiro Moreno, Stéphane Nottin, et al.. Image-based patient-specific simulation: a computational modelling of the human left heart haemodynamics. Congrès de la Société de Biomécanique, Oct 2012, Toulouse, France. 15, Supplement 1, pp.74-75, 2012, Computer Methods in Biomechanics and Biomedical Engineering. <10.1080/10255842.2012.713673>. <hal-00820857>

Chapitre d'ouvrage1 document

Thèse1 document

  • Simon Mendez. SIMULATION NUMERIQUE ET MODELISATION
    DE L'ECOULEMENT AUTOUR DES PAROIS MULTI-PERFOREES. Dynamique des Fluides [physics.flu-dyn]. Université Montpellier II - Sciences et Techniques du Languedoc, 2007. Français. <tel-00339810>