Nombre de documents

185

Hervé Liebgott


Article dans une revue55 documents

  • V. Perrot, S. Salles, D. Vray, H. Liebgott. Video Magnification Applied in Ultrasound. IEEE Transactions on Biomedical Engineering, Institute of Electrical and Electronics Engineers, 2019, 66 (1), pp.283-288. 〈10.1109/TBME.2018.2820384〉. 〈hal-01894170〉
  • Philippe Joos, Jonathan Porée, Hervé Liebgott, Didier Vray, Mathilde Baudet, et al.. High-frame-rate speckle-tracking echocardiography. IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control, Institute of Electrical and Electronics Engineers, 2018, 65 (5), pp.720 - 728. 〈10.1109/TUFFC.2018.2809553〉. 〈hal-01825296〉
  • Lorena Petrusca, François Varray, Remi Souchon, Adeline Bernard, Jean-Yves Chapelon, et al.. Fast Volumetric Ultrasound B-Mode and Doppler Imaging with a New High-Channels Density Platform for Advanced 4D Cardiac Imaging/Therapy. Applied Sciences, MDPI, 2018, 8 (2), 〈10.3390/app8020200〉. 〈hal-01699658〉
  • Roux Emmanuel, François Varray, Lorena Petrusca, Christian Cachard, Piero Tortoli, et al.. Experimental 3-D Ultrasound Imaging with 2-D Sparse Arrays using Focused and Diverging Waves. Scientific Reports, Nature Publishing Group, 2018, 8 (1), pp.9108 - 9108. 〈10.1038/s41598-018-27490-2〉. 〈hal-01839963〉
  • Emmanuel Roux, Alessandro Ramalli, Hervé Liebgott, Christian Cachard, Marc C. Robini, et al.. Wideband 2-D Array Design Optimization With Fabrication Constraints for 3-D US Imaging. IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control, Institute of Electrical and Electronics Engineers, 2017, 64 (1), pp.108 - 125. 〈10.1109/TUFFC.2016.2614776〉. 〈hal-01438361〉
  • Maxime Gasse, Fabien Millioz, Roux Emmanuel, Damien Garcia, Hervé Liebgott, et al.. High-Quality Plane Wave Compounding using Convolutional Neural Networks. IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control, Institute of Electrical and Electronics Engineers, 2017, 64 (10), pp.1637-1639. 〈10.1109/TUFFC.2017.2736890〉. 〈hal-01596034〉
  • Emeline Turquin, Lorena Petrusca, Olivier Bernard, Magalie Viallon, Hervé Liebgott, et al.. Local Orientation Imaging for Tissue Structure Using Ultrasound Imaging. IRBM, Elsevier Masson, 2017, 38 (5), pp.298 - 303. 〈10.1016/j.irbm.2017.08.002〉. 〈hal-01596136〉
  • Nora Ouzir, Adrian Basarab, Hervé Liebgott, Brahim Harbaoui, Jean-Yves Tourneret. Motion Estimation in Echocardiography Using Sparse Representation and Dictionary Learning. IEEE Transactions on Image Processing, Institute of Electrical and Electronics Engineers, 2017, vol. 27 (n° 1), pp.64-77. 〈10.1109/TIP.2017.2753406〉. 〈hal-01677873〉
  • Yue Zhao, Yi Shen, Adeline Bernard, Christian Cachard, Hervé Liebgott. Evaluation and comparison of current biopsy needle localization and tracking methods using 3D ultrasound. Ultrasonics, Elsevier, 2017, 73, pp.206-220. 〈10.1016/j.ultras.2016.09.006〉. 〈hal-01438325〉
  • Vincent Perrot, S. Meier, A. Bel-Brunon, H. Walter-Le Berre, B. Bou-Saïd, et al.. Biofidelic Abdominal Aorta Phantom: Cross-Over Preliminary Study Using UltraSound and Digital Image Stereo-Correlation. IRBM, Elsevier Masson, 2017, 38 (4), pp.238-244. 〈10.1016/j.irbm.2017.07.002〉. 〈hal-01684548〉
  • Miaomiao Zhang, Francois Varray, Adrien Besson, Rafael Carrillo, Magalie Viallon, et al.. Extension of Fourier-Based Techniques for Ultrafast Imaging in Ultrasound With Diverging Waves. IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control, Institute of Electrical and Electronics Engineers, 2016, 63 (12), pp.2125 - 2137. 〈10.1109/TUFFC.2016.2616300〉. 〈hal-01433038〉
  • Adrien Besson, Miaomiao Zhang, Francois Varray, Hervé Liebgott, Denis Friboulet, et al.. A Sparse Reconstruction Framework for Fourier-Based Plane-Wave Imaging. IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control, Institute of Electrical and Electronics Engineers, 2016, 63 (12), pp.2092 - 2106. 〈10.1109/TUFFC.2016.2614996〉. 〈hal-01433056〉
  • Oana Lorintiu, Hervé Liebgott, Olivier Bernard, Denis Friboulet. Compressed sensing Doppler ultrasound reconstruction using block sparse Bayesian learning. IEEE Transactions on Medical Imaging, Institute of Electrical and Electronics Engineers, 2016, 35, pp.978-987. 〈10.1109/TMI.2015.2504240〉. 〈hal-01274672〉
  • Emmanuel Roux, Alessandro Ramalli, Piero Tortoli, Christian Cachard, Marc C. Robini, et al.. 2-D Ultrasound Sparse Arrays Multidepth Radiation Optimization Using Simulated Annealing and Spiral-Array Inspired Energy Functions. IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control, Institute of Electrical and Electronics Engineers, 2016, 63 (12), pp.2138 - 2149. 〈10.1109/TUFFC.2016.2602242〉. 〈hal-01438338〉
  • Brahim Harbaoui, Mathieu Montoy, Paul Charles, Loic Boussel, Hervé Liebgott, et al.. Aorta calcification burden: Towards an integrative predictor of cardiac outcome after transcatheter aortic valve implantation. Atherosclerosis, Elsevier, 2016, 246, pp.161-168. 〈10.1016/j.atherosclerosis.2016.01.013〉. 〈hal-01373285〉
  • Piero Tortoli, Matteo Lenge, Daniele Righi, Gabriele Ciuti, Hervé Liebgott, et al.. Comparison of Carotid Artery Blood Velocity Measurements by Vector and Standard Doppler Approaches. Ultrasound in Medicine and Biology, Elsevier, 2015, 41 (5), pp.1354-1362. 〈10.1016/j.ultrasmedbio.2015.01.008〉. 〈hal-01213930〉
  • X. Guo, H. Liebgott, Denis Friboulet. Back-Propagation Beamformer Design for Motion Estimation in Echocardiography. Ultrasonic Imaging, SAGE Publications (UK and US), 2015, 37 (3), pp.179-204 〈10.1177/0161734614550659 〉. 〈hal-01117518〉
  • Matteo Lenge, Alessandro Ramalli, Piero Tortoli, Christian Cachard, Hervé Liebgott. Plane-Wave Transverse Oscillation for High-Frame-Rate 2-D Vector Flow Imaging. IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control, Institute of Electrical and Electronics Engineers, 2015, 62 (12), pp.2126-2137. 〈10.1109/TUFFC.2015.007320〉. 〈hal-01235764〉
  • Sébastien Salles, Adrian Chee, Damien Garcia, Alfred Yu, Didier Vray, et al.. 2-D arterial wall motion imaging using ultrafast ultrasound and transverse oscillations. IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control, Institute of Electrical and Electronics Engineers, 2015, 62 (6), pp.1047-1058. 〈10.1109/TUFFC.2014.006910〉. 〈hal-01235722〉
  • Sébastien Salles, Hervé Liebgott, Damien Garcia, Didier Vray. Full 3-D transverse oscillations: a method for tissue motion estimation. IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control, Institute of Electrical and Electronics Engineers, 2015, 62 (8), pp.1473 - 1485. 〈10.1109/TUFFC.2015.007050〉. 〈hal-01235740〉
  • Oana Lorintiu, Herve Liebgott, Martino Alessandrini, Olivier Bernard, Denis Friboulet. Compressed sensing reconstruction of 3D ultrasound data using dictionary learning and line-wise subsampling. IEEE Transactions on Medical Imaging, Institute of Electrical and Electronics Engineers, 2015, 34 (12), pp.2467-2477. 〈10.1109/TMI.2015.2442154〉. 〈hal-01180189〉
  • G. Zahnd, S. Salles, A. Sérusclat, Philippe Moulin, H. Liebgott, et al.. Real-time ultrasound-tagging to track the 2D motion of the common carotid artery wall in vivo. Medical Physics, American Association of Physicists in Medicine, 2015, 42 (8), pp.820-830. 〈10.1118/1.4905376〉. 〈hal-01207368〉
  • Y. Zhao, A. Bernard, C. Cachard, H. Liebgott. Biopsy needle localization and tracking using ROI-RK method. Abstract and Applied Analysis, Hindawi Publishing Corporation, 2014, in press. 〈hal-01955138〉
  • Y. Zhao, H. Liebgott, C. Cachard. A comparison of the existing tool localization methods on 2D ultrasound images and their tracking results. IET Control Theory & Applications, 2014, in press. 〈hal-01955139〉
  • S. Salles, H. Liebgott, O. Basset, C. Cachard, D. Vray, et al.. Experimental Evaluation of Spectral-Based Quantitative Ultrasound Imaging Using Plane Wave Compounding. IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 2014, 61 (11), pp.1824-1834. 〈10.1109/TUFFC.2014.006543〉. 〈hal-01955137〉
  • Matteo Lenge, Alessandro Ramalli, Enrico Boni, Hervé Liebgott, Christian Cachard, et al.. High-frame-rate 2-D vector blood flow imaging in the frequency domain. IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control, Institute of Electrical and Electronics Engineers, 2014, 61 (9), pp.1504-1514. 〈10.1109/TUFFC.2014.3064〉. 〈hal-02064579〉
  • Martino Alessandrini, Adrian Basarab, Loic Boussel, Xinxin Guo, André Serusclat, et al.. A New Technique for the Estimation of Cardiac Motion in Echocardiography Based on Transverse Oscillations: a preliminary evaluation in silico and a feasibility demonstration in vivo. IEEE Transactions on Medical Imaging, Institute of Electrical and Electronics Engineers, 2014, vol. 33 (n° 5), pp. 1148-1162. 〈10.1109/TMI.2014.2305846〉. 〈hal-01117833〉
  • Bernard Gibaud, Germain Forestier, Hugues Benoit-Cattin, Frédéric Cervenansky, Patrick Clarysse, et al.. OntoVIP: An ontology for the annotation of object models used for medical image simulation.. Journal of Biomedical Informatics, Elsevier, 2014, 52, pp.279-92. 〈10.1016/j.jbi.2014.07.008〉. 〈inserm-01062371〉
  • Benoît Presles, Marie Fargier-Voiron, Marie-Claude Biston, Rod Lynch, Alexandre Munoz, et al.. Semiautomatic registration of 3D transabdominal ultrasound images for patient repositioning during postprostatectomy radiotherapy. Journal of Medical Physics, Medknow Publications, 2014, 41 (12), pp.122903. 〈10.1118/1.4901642〉. 〈hal-01124439〉
  • M. Fargier-Voiron, B. Presles, P. Pommier, S. Rit, A. Munoz, et al.. Impact of probe pressure variability on prostate localization for ultrasound-based image-guided radiotherapy. Radiotherapy and Oncology, Elsevier, 2014, 111 (1), pp.132-137. 〈10.1016/j.radonc.2014.02.008〉. 〈hal-00977068〉
  • Y. Zhao, C. Cachard, H. Liebgott. Automatic Needle Detection and Tracking in 3D Ultrasound Using an ROI-Based RANSAC and Kalman Method. Ultrasonic Imaging, SAGE Publications (UK and US), 2013, 35 (4), pp.283-306. 〈10.1177/0161734613502004〉. 〈hal-00872636〉
  • F. Varray, H. Liebgott. Multi-resolution transverse oscillation in ultrasound imaging for motion estimation. IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control, Institute of Electrical and Electronics Engineers, 2013, 60 (7), pp.1333-1342. 〈10.1109/TUFFC.2013.2707〉. 〈hal-00850036〉
  • Tristan Glatard, Carole Lartizien, Bernard Gibaud, Rafael Ferreira da Silva, Germain Forestier, et al.. A virtual imaging platform for multi-modality medical image simulation.. IEEE Transactions on Medical Imaging, Institute of Electrical and Electronics Engineers, 2013, 32 (1), pp.110-8. 〈10.1109/TMI.2012.2220154〉. 〈inserm-00762497〉
  • J. Richy, D. Friboulet, A. Bernard, Olivier Bernard, H. Liebgott. Blood Velocity Estimation Using Compressive Sensing. IEEE Transactions on Medical Imaging, Institute of Electrical and Electronics Engineers, 2013, 32 (11), pp.1979-1988. 〈10.1109/TMI.2013.2266871〉. 〈hal-00839213〉
  • Mathieu De Craene, Stéphanie Marchesseau, Brecht Heyde, Hang Gao, M. Alessandrini, et al.. 3D strain assessment in ultrasound (straus): A synthetic comparison of five tracking methodologies. IEEE Transactions on Medical Imaging, Institute of Electrical and Electronics Engineers, 2013, 32 (9), pp.1632 - 1646. 〈10.1109/TMI.2013.2261823〉. 〈hal-00840039〉
  • Martino Alessandrini, Adrian Basarab, Hervé Liebgott, Olivier Bernard. Myocardial Motion Estimation from Medical Images Using the Monogenic Signal. IEEE Transactions on Image Processing, Institute of Electrical and Electronics Engineers, 2013, vol. 22 (n° 3), pp. 1084-1095. 〈10.1109/TIP.2012.2226903〉. 〈hal-01121047〉
  • Martino Alessandrini, Adrian Basarab, Hervé Liebgott, Olivier Bernard. Myocardial Motion Estimation from Medical Images Using the Monogenic Signal. IEEE Transactions on Image Processing, Institute of Electrical and Electronics Engineers, 2013, 22 (3), pp.1084-1095. 〈10.1109/TIP.2012.2226903〉. 〈hal-00819357〉
  • B. Diarra, M. Robini, P. Tortoli, C. Cachard, H. Liebgott. Design of optimal 2-D non-grid sparse arrays for medical ultrasound. IEEE Transactions on Biomedical Engineering, Institute of Electrical and Electronics Engineers, 2013, 60 (11), pp.3093-3102. 〈10.1109/TBME.2013.2267742〉. 〈hal-00850032〉
  • K. Holst, H. Liebgott, J. E. Wilhjelm, S. Nikolov, S. T. Torp-Pedersend, et al.. Internal Strain Estimation for Quantification of Human Heel Pad Elastic Modulus: a Phantom Study. Ultrasonics, Elsevier, 2013, 53 (2), pp.439-446. 〈10.1016/j.ultras.2012.08.009〉. 〈hal-00797778〉
  • H. Liebgott, R. Prost, D. Friboulet. Pre-beamformed RF signal reconstruction in medical ultrasound using compressive sensing. Ultrasonics, Elsevier, 2013, 53 (2), pp.525-533. 〈10.1016/j.ultras.2012.09.008〉. 〈hal-00798017〉
  • M. Uhercik, J. Kybic, Y. Zhao, C. Cachard, H. Liebgott. Line Filtering for Surgical Tool Localization in 3D Ultrasound Images. Computers in Biology and Medicine, Elsevier, 2013, 43 (12). 〈hal-01955141〉
  • Martino Alessandrini, Olivier Bernard, Adrian Basarab, Hervé Liebgott. Multiscale optical flow computation from the monogenic signal. IRBM, Elsevier Masson, 2013, vol. 34 (n° 1), pp. 33-37. 〈10.1016/j.irbm.2012.12.015〉. 〈hal-01121528〉
  • M. Uhercik, J. Kybic, H. Liebgott, C. Cachard. Model Fitting using RANSAC for Surgical Tool Localization in 3D Ultrasound Images. IEEE Transactions on Biomedical Engineering, Institute of Electrical and Electronics Engineers, 2010, 57 (8), pp.1907-1916. 〈10.1109/TBME.2010.2046416〉. 〈hal-01955149〉
  • H. Liebgott, A. Basarab, P. Gueth, D. Friboulet, Philippe Delachartre. Transverse oscillations for tissue motion estimation. Ultrasonics, Elsevier, 2010, 50 (6), pp.548-555. 〈10.1016/j.ultras.2009.11.001〉. 〈hal-01919844〉
  • A. Basarab, P. Gueth, H. Liebgott, Philippe Delachartre. Phase-based block matching applied to motion estimation with unconventional beamforming strategies. IEEE Trans Ultrason Ferroelectr Freq Control, 2009, 56 (5), pp.945-957. 〈hal-00443134〉
  • F. Duboeuf, A. Basarab, H. Liebgott, E. Brusseau, Philippe Delachartre, et al.. Investigation of PVA cryogel Young's modulus stability with time, controlled by a simple reliable technique. J Med Phys, 2009, 36 (2), pp.656--661. 〈hal-00443231〉
  • A. Basarab, H. Liebgott, Philippe Delachartre. Analytic estimation of subsample spatial shift using the phases of multidimensional analytic signals. IEEE Trans Image Proces, 2009, 18 (2), pp.440-447. 〈hal-00443135〉
  • M. Barva, M. Uhercik, J. M. Mari, J. Kybic, J. R. Duhamel, et al.. Parallel integral projection transform for straight electrode localization in 3D ultrasound. IEEE Trans Ultrason Ferroelectr Freq Control, 2008, 55 (7), pp.1559-1569. 〈hal-00443133〉
  • A. Basarab, H. Liebgott, F. Morestin, A. Lyshchik, T. Higashi, et al.. A method for vector displacement estimation with ultrasound images and its application for thyroid nodular disease. Med Image Anal, Elsevier, 2008, 12 (3), pp.259-274. 〈hal-00443136〉
  • H. Liebgott, A. Basarab, P. Gueth, C. Cachard, Philippe Delachartre. Lateral RF image synthesis using a synthetic aperture imaging technique. IEEE Trans Ultrason Ferroelectr Freq Control, 2008, 55 (9), pp.2097-2103. 〈hal-00443319〉
  • H. Liebgott, J. E. Wilhjelm, J. A. Jensen, D. Vray, Philippe Delachartre. PSF dedicated to estimation of displacement vectors for tissue elasticity imaging with ultrasound. IEEE Trans Ultrason Ferroelectr Freq Control, 2007, 54 (4), pp.746--756. 〈hal-00443321〉
  • Jérémie Fromageau, Hervé Liebgott, Elisabeth Brusseau, Didier Vray, Philippe Delachartre. Estimation of Time-Scaling Factor for Ultrasound Medical Images Using the Hilbert Transform. EURASIP Journal on Advances in Signal Processing, SpringerOpen, 2007, 2007 (1), pp.080735. 〈inserm-00641301〉
  • Philippe Delachartre, H. Liebgott, F. Lacouture, F. Morestin, A. Lyshchik, et al.. Modelisation bilineaire et estimation du deplacement pour l'imagerie de l'elasticite appliquee au cancer de la thyroide. Traitement du Signal, Lavoisier, 2006, 23 (3/4), pp.235-245. 〈hal-00443221〉
  • W. Aoudi, H. Liebgott, A. Needles, V. Yang, F. S. Foster, et al.. Estimation Methods for Flow Imaging with High Frequency Ultrasound. Ultrasonics, Elsevier, 2006, 44, pp.135--140. 〈hal-00443115〉
  • Hervé Liebgott, Jérémie Fromageau, Jens Wilhjelm, Didier Vray, Philippe Delachartre. Beamforming Scheme for 2D Displacement Estimation in Ultrasound Imaging. EURASIP Journal on Advances in Signal Processing, SpringerOpen, 2005, 2005 (8), pp.932740. 〈inserm-00640131〉

Communication dans un congrès122 documents

  • P. Mattesini, G. Le Moign, E. Roux, E. Badescu, L. Petrusca, et al.. Optimal virtual sources distribution in 3-D diverging wave US imaging. IEEE International Ultrasonics Symposium, 2018, Kobe, Japan. 2018. 〈hal-01955120〉
  • P. Mattesini, A. Ramalli, E. Roux, L. Petrusca, H. Liebgott, et al.. Specral Doppler measurments with 2D sparse arrays. IEEE International Ultrasonics Symposium, 2018, Kobe, Japan. 2018. 〈hal-01955121〉
  • Denis Bujoreanu, Yanis Mehdi Benane, Barbara Nicolas, Hervé Liebgott, Jean-Marie Gorce, et al.. Jointly Optimized Modulation/Filtering Technique for Pseudo-Orthogonal Binary Sequences. International Ultrasonics Symposium, Oct 2018, Kobe, Japan. pp.1-5, 2018, 〈10.1109/ULTSYM.2018.8580025〉. 〈hal-01987969〉
  • D. Bujoreanu, Y.M. Benane, H Liebgott, Barbara Nicolas, O. Basset, et al.. A Resolution Enhancement Technique for Ultrafast Coded Medical Ultrasound. European Signal Processing Conference (Eusipco), 2018, Rome, Italy. pp.1-5, 2018. 〈hal-01922104〉
  • E. Badescu, S. Ambrogio, J. Fenner, H. Liebgott, D. Friboulet, et al.. Vortex ring phantom for investigation of ultrasound vector flow. IEEE International Ultrasonics Symposium, 2018, Kobe, Japan. pp.1-4, 2018. 〈hal-01894169〉
  • E. Badescu, L. Petrusca, D. Friboulet, H. Liebgott. Experimental cross-talk reduction for 3D multi-line transmission. IEEE International Ultrasonics Symposium, 2018, Kobe, Japan. pp.1-4, 2018. 〈hal-01894165〉
  • M. Polichetti, V. Perrot, H. Liebgott, B. Nicolas, F. Varray. Influence of Beamforming Methods on Velocity Estimation: In Vitro Experiments. IEEE International Ultrasonic Symposium, 2018, Kobe, Japan. 2018, 2018 IEEE International Ultrasonics Symposium (IUS). 〈10.1109/ULTSYM.2018.8580186〉. 〈hal-01894167〉
  • Vincent Perrot, Jørgen Avdal, Lasse Løvstakken, Sébastien Salles, Didier Vray, et al.. Spatial and Temporal Adaptive FIR Clutter Filtering. 2018 IEEE International Ultrasonics Symposium (IUS), Oct 2018, Kobe, Japan. IEEE, pp.1-4, 2018 IEEE International Ultrasonics Symposium (IUS). 〈10.1109/ULTSYM.2018.8579766〉. 〈hal-02063569〉
  • Alfonso Rodriguez-Molares, Ole Marius Hoel Rindal, Olivier Bernard, Hervé Liebgott, Andreas Austeng, et al.. The UltraSound ToolBox. 2017 IEEE International Ultrasonic Symposium (IUS), Sep 2017, Washington, United States. 2017. 〈hal-01599351〉
  • Miaomiao Zhang, Hervé Liebgott, François Varray, Denis Friboulet, Olivier Bernard. Fourier-Based Ultrafast Ultrasound Imaging Based on In-phase Quadrature (IQ) Data. 2017 IEEE International Ultrasonic Symposium (IUS), Sep 2017, Washington, United States. 2017. 〈hal-01599416〉
  • Zhang Miaomiao, Francois Varray, Lorena Petrusca, Denis Friboulet, Hervé Liebgott, et al.. Fourier-based 3D Ultrafast Ultrasound Imaging with Diverging Waves: In Vitro Experiment Validation. 2017 IEEE International Ultrasonic Symposium (IUS), Sep 2017, Washington, United States. 2017. 〈hal-01599710〉
  • Denis Bujoreanu, Denis Friboulet, Barbara Nicolas, Hervé Liebgott. Simultaneous coded plane wave imaging in ultrasound: problem formulation and constraints. IEEE International Conference on Acoustics, Speech and Signal Processing (ICASSP), 2017, Mar 2017, New Orleans, United States. IEEE ICASSP Proceedings. 〈10.1109/ICASSP.2017.7953359〉. 〈hal-01572492〉
  • David Rousseau, Bonet Axel, Bruno Montcel, Cédric Ray, Kevin Tse Ve Koon, et al.. Plateforme didactique mutualisée de travaux pratiques en instrumentation et imagerie biomédicale. 12ème édition du colloque du Club EEA consacré à l'Enseignement des Technologies de l'Information et des Systèmes - CETSIS 2017, May 2017, Le Mans, France. 2017. 〈hal-01598498〉
  • Philippe Joos, Hervé Liebgott, François Varray, Lorena Petrusca, Damien Garcia, et al.. High-Volume-Rate 3-D Ultrasound Imaging Based on Motion Compensation: A Feasibility Study. 2017 IEEE International Ultrasonic Symposium (IUS), Sep 2017, Washington, United States. 2017. 〈hal-01609166〉
  • Maxime Gasse, Fabien Millioz, Roux Emmanuel, Hervé Liebgott, Denis Friboulet. Accelerating Plane Wave Imaging through Deep Learning-Based Reconstruction: An Experimental Study. 2017 IEEE International Ultrasonic Symposium (IUS), Sep 2017, Washington, United States. 2017. 〈hal-01609173〉
  • Denis Bujoreanu, Adeline Bernard, Barbara Nicolas, Hervé Liebgott, Denis Friboulet. Simultaneous Coded Plane Wave Imaging: Implementation on a Research Echograph. 2017 IEEE International Ultrasonic Symposium (IUS), Sep 2017, Washington, United States. 2017. 〈hal-01599409〉
  • Emeline Turquin, Lorena Petrusca, Olivier Bernard, Magalie Viallon, Hervé Liebgott, et al.. IMAGERIE DE L’ORIENTATION LOCALE DE LA STRUCTURE TISSULAIRE PAR IMAGERIE ULTRASONORE. Recherche en Imagerie et Technologies pour la Santé (RITS) 2017, Mar 2017, Lyon, France. 〈hal-01505208〉
  • Lorena Petrusca, Francois Varray, Rémi Souchon, Adeline Bernard, Jean-Yves Chapelon, et al.. A New High Channels Density Ultrasound Platform for Advanced 4D Cardiac Imaging. 2017 IEEE International Ultrasonic Symposium (IUS), Sep 2017, Washington, United States. 2017. 〈hal-01599683〉
  • Magalie Viallon, Lorena Petrusca, William Apoutou N'Djin, Claire Crola Da Silva, Nathan Mewton, et al.. METHODOLOGIES ACOUSTIQUES DANS LE TRAITEMENT DE LA PHASE AIGUË DE L’INFARCTUS DU MYOCARDE. Recherche en Imagerie et Technologies pour la Santé (RITS) 2017, Mar 2017, Lyon, France. 〈hal-01504967〉
  • Roux Emmanuel, Emilia Badescu, Lorena Petrusca, Francois Varray, Alessandro Ramalli, et al.. Validation of Optimal 2D Sparse Arrays in Focused Mode: Phantom Experiments. 2017 IEEE International Ultrasonic Symposium (IUS), Sep 2017, Washington, United States. 2017. 〈hal-01598578〉
  • Emilia Badescu, Lorena Petrusca, Damien Garcia, Denis Friboulet, Hervé Liebgott. Doppler Velocity Estimation in 3d Cardiac Ultrafast Ultrasound Imaging: An In Vitro Study. 2017 IEEE International Ultrasonic Symposium (IUS), Sep 2017, Washington, United States. 2017. 〈hal-01598539〉
  • Emilia Badescu, Denis Bujoreanu, Lorena Petrusca, Denis Friboulet, Hervé Liebgott. Multi-line Transmission for 3d Ultrasound Imaging: An Experimental Study. 2017 IEEE International Ultrasonic Symposium (IUS), Sep 2017, Washington, United States. 2017. 〈hal-01599744〉
  • Vincent Perrot, Lorena Petrusca, Adeline Bernard, Didier Vray, Herve Liebgott. Simultaneous pulse wave and flow estimation at high-framerate using plane wave and transverse oscillation on carotid phantom. IEEE International Ultrasonics Symposium, 2017, Washington, USA, United States. 2017, 2017 IEEE International Ultrasonics Symposium (IUS). 〈10.1109/ULTSYM.2017.8091999〉. 〈hal-01894173〉
  • Philippe Joos, Jonathan Porée, Hervé Liebgott, Didier Vray, Guy Cloutier, et al.. High-frame-rate velocity vector imaging echocardiography: an in vitro evaluation. 2016 IEEE International Ultrasonics Symposium (IUS), Sep 2016, Tours, France. Proceedings of the 2016 IEEE International Ultrasonics Symposium (IUS). 〈10.1109/ULTSYM.2016.7728784〉. 〈hal-01439630〉
  • Zhang Miaomiao, Hervé Liebgott, Francois Varray, Denis Friboulet, Olivier Bernard. A Fourier-based formalism for 3D ultrafast imaging with diverging waves. IEEE International Ultrasonics Symposium (IUS 2016), Sep 2016, Tours, France. 〈10.1109/ULTSYM.2016.7728805〉. 〈hal-01433084〉
  • Herve Liebgott, A Rodriguez-Molares, F. Cervenansky, Jørgen Arendt Jensen, Olivier Bernard. Plane-wave imaging challenge in medical ultrasound. Ultrasonics Symposium (IUS), 2016 IEEE International, 2016, Unknown, Unknown Region. pp.1--4, 2016. 〈hal-01792365〉
  • Bakary Diarra, Emmanuel Roux, Hervé Liebgott, Samikannu Ravi, Marc C. Robini, et al.. Comparison of different optimized irregular sparse 2D ultrasound arrays. 2016 IEEE International Ultrasonics Symposium (IUS), Sep 2016, Tours, France. 2016, Proceedings of the 2016 IEEE International Ultrasonics Symposium (IUS). 〈10.1109/ULTSYM.2016.7728414〉. 〈hal-01438438〉
  • S. Salles, A. Long, L. Petrusca, V. Perrot, D. Vray, et al.. Estimation of arterial wall motion using ultrafast imaging and transverse oscillations : in vivo study. IEEE International Ultrasonics Symposium, 2016, Tours, France., Unknown Region. accepted, 2016. 〈hal-01955125〉
  • H. Liebgott. Transverse oscillations a method for vector motion estimation in cardiovascular applications. no-book, 2016, Caparica, Lisbon, Portugal. Ultrasonics 2016: 2cd International Conference on ultrasonic based applications: from analysis to synthesis, 2016. 〈hal-01955126〉
  • Emilia Badescu, Sébastien Salles, Didier Vray, Denis Friboulet, Hervé Liebgott. A measure of confidence for Phase-Based Motion Estimator applied to 2D US-TO images. 2016 IEEE International Ultrasonics Symposium (IUS), Sep 2016, Tours, France. Proceedings of the 2016 IEEE International Ultrasonics Symposium (IUS). 〈10.1109/ULTSYM.2016.7728601〉. 〈hal-01437598〉
  • Sébastien Salles, Anne Long, Lorena Petrusca, Vincent Perrot, Didier Vray, et al.. Estimation of arterial wall motion using ultrafast imaging and transverse oscillations: in vivo study. IEEE International Ultrasonics Symposium (IUS 2016), Sep 2016, Tours, France. IEEE International Ultrasonics Symposium (IUS 2016), Proceedings of the 2016 IEEE International Ultrasonics Symposium (IUS). 〈10.1109/ULTSYM.2016.7728749〉. 〈hal-01438446〉
  • E. Roux, A. Ramalli, P. Tortoli, C. Cachard, M. Robini, et al.. Speed-up of acoustic simulation techniques for 2D sparse array optimization by simulated annealing. Ultrasonics Symposium (IUS), 2015 IEEE International, Oct 2015, Taipei, Taiwan. IEEE, pp.1 - 4 2015, Ultrasonics Symposium (IUS), 2015 IEEE International. 〈10.1109/ULTSYM.2015.0431〉. 〈hal-01272818〉
  • Oana Lorintiu, Hervé Liebgott, Olivier Bernard, Denis Friboulet. Sub-sampled Doppler ultrasound reconstruction using block sparse Bayesian learning. Ultrasonics Symposium (IUS), 2015 IEEE International, Oct 2015, Taipei, Taiwan. IEEE, Ultrasonics Symposium (IUS), 2015 IEEE International. 〈10.1109/ULTSYM.2015.0321〉. 〈hal-01265868〉
  • Emmanuel Roux, Alessandro Ramalli, Marc C. Robini, Hervé Liebgott, Christian Cachard, et al.. Spiral array inspired multi-depth cost function for 2D sparse array optimization. Ultrasonics Symposium (IUS), 2015 IEEE International, Oct 2015, Taipei, Taiwan. IEEE, Ultrasonics Symposium (IUS), 2015 IEEE International 〈10.1109/ULTSYM.2015.0096〉. 〈hal-01265828〉
  • Philippe Joos, Sébastien Salles, Didier Vray, Barbara Nicolas, Hervé Liebgott. Cardiac Motion estimation based on transverse oscillation and ultrafast diverging wave imaging. Ultrasonics Symposium (IUS), 2015 IEEE International, Oct 2015, Taipei, Taiwan. IEEE, Ultrasonics Symposium (IUS), 2015 IEEE International. 〈10.1109/ULTSYM.2015.0220〉. 〈hal-01265859〉
  • Martino Alessandrini, Adrian Basarab, Mathieu De Craene, Maxime Sermesant, Hervé Liebgott, et al.. The role of the image phase in cardiac strain imaging. EUSIPCO 2015 - 23rd European Signal Processing Conference, Aug 2015, Nice, France. IEEE, 2015 23rd European Signal Processing Conference (EUSIPCO), pp.2796-2800, 2015, 〈10.1109/EUSIPCO.2015.7362894〉. 〈hal-01265886v2〉
  • Oana Lorintiu, Hervé Liebgott, Adeline Bernard, Olivier Bernard, Denis Friboulet. Compressed sensing reconstruction of line-wise sub-sampled 3D echographic images based on dictionary learning: an experimental study. Ultrasonics Symposium (IUS), 2015 IEEE International, Oct 2015, Taipei, Taiwan. IEEE, 〈10.1109/ULTSYM.2015.0157〉. 〈hal-01265811〉
  • Zhang Miaomiao, Adrien Besson, Rafael Carrillo, Francois Varray, Magalie Viallon, et al.. Extension of Ultrasound Fourier Slice Imaging theory to sectorial acquisition. Ultrasonics Symposium (IUS), 2015 IEEE International, Oct 2015, Taipei, Taiwan. IEEE, Ultrasonics Symposium (IUS), 2015 IEEE International. 〈10.1109/ULTSYM.2015.0185〉. 〈hal-01265845〉
  • Emmanuel Roux, Marc C. Robini, Alessandro Ramalli, Piero Tortoli, Christian Cachard, et al.. Modélisation et simulation acoustique pour l’optimisation de sondes échographiques 2D par recuit simulé. XXVème Colloque GRETSI, Sep 2015, Lyon, France. 〈hal-01286079〉
  • Nathan Pages, Hervé Liebgott, Barbara Nicolas. Emissions codées par ondes planes en imagerie ultrasonore ultra-rapide. Colloque GRETSI, Sep 2015, Lyon, France. 2015. 〈hal-01232553〉
  • Olivier Bernard, M. Zhang, F. Varray, P. Gueth, Jean-Philippe Thiran, et al.. Ultrasound Fourier slice imaging: a novel approach for ultrafast imaging technique. IEEE International Ultrasonics Symposium (IUS) 2014, Sep 2014, Chicago, United States. IEEE, pp.129 - 132, 2014, Ultrasonics Symposium (IUS), 2014 IEEE International. 〈10.1109/ULTSYM.2014.0033〉. 〈hal-01117623〉
  • M. Fargier-Voiron, B. Presles, P. Pommier, S. Rit, A. Munoz, et al.. Impact of probe pressure variability on prostate localization for ultrasound-based image-guided radiotherapy. ESTRO 33, Apr 2014, Vienne, Austria. pp.PO-0990, 2014. 〈hal-01053245〉
  • B. Presles, M. Fargier-Voiron, M.-C. Biston, R. Lynch, A. Munoz, et al.. Recalage automatique d'images ultrasonores tridimensionnelles transabdominales pour le repositionnement inter-séances de patients traités par radiothérapie ayant subis une prostatectomie radicale. 9ème journée scientifique du CLARA, Jun 2014, Lyon, France. 〈hal-01054202〉
  • S. Salles, D. Garcia, B. Bou-Sa\"ıd, F. Savary, A. Sérusclat, et al.. Plane Wave Transverse Oscillation (PWTO): an ultra-fast trans-verse oscillation imaging mode performed in the Fourier domain for 2D motion estimation of the carotid artery. ISBI 2014, 2014, Unknown, Unknown Region. IEEE, 2014. 〈hal-01955129〉
  • M. Lenge, D. Righi, S. Ricci, H. Liebgott, P. Tortoli. Blood velocity measurement in healthy and diseased carotid arteries by vector Doppler techniques. IEEE International Ultrasonics Symposium, 2014, Chicago, Illinois, USA, Unknown Region. 2014. 〈hal-01955130〉
  • E. Roux, B. Diarra, M. Robini, C. Cachard, P. Tortoli, et al.. Realistic acoustic simulation of 2D probe elements in simulated annealing sparse array optimization. IEEE International Ultrasonics Symposium, 2014, Chicago, Illinois, USA, Unknown Region. pp.2125\textendash2128, 2014. 〈hal-01955131〉
  • S. Salles, S. Lai, D. Garcia, A. Yu, D. Vray, et al.. Estimation of arterial wall motion using ultrafast imaging with transverse oscillations. IEEE International Ultrasonics Symposium, 2014, Unknown, Unknown Region. 2014. 〈hal-01955133〉
  • B. Diarra, M. Robini, E. Roux, P. Tortoli, H. Liebgott, et al.. Optimization of free-moving elements in 2D ultrasound sparse arrays. IEEE International Ultrasonics Symposium, 2014, Chicago, Illinois, USA, Unknown Region. pp.2189\textendash2192, 2014. 〈hal-01955134〉
  • F. Varray, H. Liebgott, C. Cachard, D. Vray. Simulation of Fast and Realistic Nonlinear Radio-Frequency Ultrasound Images Using a Pseudo-Acoustic Strategy. IEEE International Ultrasonics Symposium, 2014, Chicago, USA, Unknown Region. pp.2217-2220, 2014, 〈10.1109/ULTSYM.2014.0552〉. 〈hal-01955135〉
  • M. Lenge, A. Ramalli, A. Cellai, P. Tortoli, C. Cachard, et al.. A new method for 2D-vector blood flow imaging based on unconventional beamforming techniques. IEEE International Conference on Acoustics, Speech and Signal Processing (ICASSP), 2014, May 2014, Florence, Italy. pp.5125 - 5129, 2014, 〈10.1109/ICASSP.2014.6854579〉. 〈hal-01051090〉
  • O. Lorintiu, H. Liebgott, M. Alessandrini, Olivier Bernard, Denis Friboulet. Compressed sensing reconstruction of 3D ultrasound data using dictionary learning. IEEE International Conference on Image Processing (ICIP) 2014, Oct 2014, Paris, France. pp.1317-1321, 2014, Image Processing (ICIP), 2014 IEEE International Conference on. 〈10.1109/ICIP.2014.7025263〉. 〈hal-01117604〉
  • M. Zhang, H. Liebgott, F. Varray, Denis Friboulet, Olivier Bernard. Speckle decorrelation of motion in Ultrasound Fourier images. IEEE International Ultrasonics Symposium (IUS) 2014, Sep 2014, Chicago, France. pp.1203 - 1206, 2014, Ultrasonics Symposium (IUS), 2014 IEEE International. 〈10.1109/ULTSYM.2014.0296〉. 〈hal-01117703〉
  • M. Alessandrini, A. Basarab, H. Liebgott, Olivier Bernard. Cardiac motion assessement from echocardiographic image sequences by means of the structure multivector. IEEE International Ultrasonics Symposium (IUS) 2013, Jul 2013, Prague, Czech Republic. IEEE, pp.1541 - 1544, 2013, 〈10.1109/ULTSYM.2013.0392〉. 〈hal-00850055〉
  • O. Lorintiu, H. Liebgott, Olivier Bernard, D. Friboulet. Compressive Sensing Ultrasound Imaging using Overcomplete Dictionaries. IEEE International Ultrasonics Symposium (IUS) 2013, Jul 2013, Prague, Czech Republic. pp.45-48, 2013. 〈hal-00850070〉
  • Martino Alessandrini, Adrian Basarab, Hervé Liebgott, Olivier Bernard. Cardiac motion assessement from echocardiographic image sequences by means of the structure multivector. IEEE International Ultrasonics Symposium - US 2013, Jul 2013, Prague, Czech Republic. Ultrasonics Symposium (IUS), 2013 IEEE International, pp. 1541-1544, 2013. 〈hal-01147282〉
  • M. Lenge, A. Ramalli, E. Boni, H. Liebgott, C. Cachard, et al.. Frequency-domain high frame-rate 2D vector flow imagin. IEEE International Ultrasonics Symposium (IUS), 2013, Prague, Czech Respublic, Unknown Region. 2013. 〈hal-01955142〉
  • D. Posada, S. Shahriari, B. Chayer, G. Cloutier, H. Liebgott, et al.. High-speed vector motion imaging with diverging circular waves: in vitro study using a spinning disc phantom. IEEE International Ultrasonics Symposium (IUS), 2013, Prague, Czech Respublic, Unknown Region. 2013. 〈hal-01955143〉
  • Adrian Basarab, Hervé Liebgott, Olivier Bernard, Denis Friboulet, Denis Kouamé. Medical ultrasound image reconstruction using distributed compressive sampling. IEEE International Symposium on Biomedical Imaging: From Nano to Macro - ISBI 2013, Apr 2013, San Francisco, United States. Biomedical Imaging (ISBI), 2013 IEEE 10th International Symposium on, pp. 628-631, 2013. 〈hal-01150347〉
  • Y. Zhao, C. Cachard, H. Liebgott. A New Automatically Biopsy Needle Tracking Method Using 3D Ultrasound. IEEE. IEEE International Ultrasonics Symposium (IUS) 2013, Jul 2013, Prague, Czech Republic. pp.844 - 847, 2013, 〈10.1109/ULTSYM.2013.0217〉. 〈hal-00850056〉
  • M. Lenge, A. Ramalli, E. Boni, H. Liebgott, C. Cachard, et al.. Frequency-domain high frame-rate 2D vector flow imaging. IEEE International Ultrasonics Symposium (IUS) 2013, Jul 2013, Prague, Czech Republic. 59 (4), pp.817-824, 2013, 〈10.1109/TUFFC.2012.2260〉. 〈hal-00850058〉
  • F. Varray, H. Liebgott. An alternative method to classical beamforming for transverse oscillation images: application to elastography. IEEE International Symposium on Biomedical Imaging (ISBI 2013), Apr 2013, San Francisco, United States. in press, 2013. 〈hal-00850048〉
  • B. Diarra, M. Robini, H. Liebgott, C. Cachard, P. Tortoli. Variable-size elements in 2D sparse arrays for 3D medical ultrasound. IEEE International Ultrasonics Symposium (IUS) 2013, Jul 2013, Prague, Czech Republic. in press, 2013. 〈hal-00850067〉
  • D. Posada, S. Dort, B. Chayer, S. Shahriari, G. Cloutier, et al.. Towards High Frame Rate Cardiac Ultrasonography - a Circular Wave Imaging Approach. IEEE International Ultrasonics Symposium (IUS) 2013, Jul 2013, Prague, Czech Republic. pp.2018 - 2021, 2013, Ultrasonics Symposium (IUS), 2013 IEEE International. 〈10.1109/ULTSYM.2013.0515〉. 〈hal-00850072〉
  • S. Salles, H. Liebgott, D. Garcia, D. Vray. Real time 3D US-tagging combined with 3D phase-based motion estimation. IEEE International Ultrasonics Symposium (IUS) 20013, Jul 2013, Prague, Czech Republic. pp.585 - 588, 2013, 〈10.1109/ULTSYM.2013.0151〉. 〈hal-00850061〉
  • Anca Cristea, Florian Aulanier, Herve Liebgott, Barbara Nicolas. Estimation of time and angle variations for perturbations in an acoustic oceanic waveguide. 1st International Conference and Exhibition on Underwater Acoustics (UA2013), Jun 2013, Corfou, Greece. pp.n/c, 2013. 〈hal-00935396〉
  • H. Liebgott, Olivier Bernard, A. Basarab, Loic Boussel, Martino Alessandrini, et al.. Oscillations transverses et estimation du mouvement échocardiographie : le Tagging Ultrasonore. SIAM - Signal et Image en Acoustique Médicale, Jun 2013, Tours, France. 〈hal-00921538〉
  • Martino Alessandrini, H. Liebgott, D. Friboulet, Olivier Bernard. Monogenic phase based myocardial motion analysis from cardiac ultrasound with transverse oscillations. IEEE International Ultrasonics Symposium 2012, Oct 2012, Dresden, Germany. 〈hal-00839216〉
  • Martino Alessandrini, H. Liebgott, Olivier Bernard. Monogenic phase based optical flow computation for myocardial motion analysis in 3D echocardiography. STACOM workshop at MICCAI 2012, Oct 2012, Nice, France. 〈hal-00839223〉
  • H. Liebgott, A. Basarab, D. Kouame, Olivier Bernard, D. Friboulet. Compressive sensing in medical ultrasound. IEEE. IEEE International Ultrasonics Symposium 2012, Oct 2012, Dresden, Germany. IEEE, pp.1-6, 〈10.1109/ULTSYM.2012.0486〉. 〈hal-00830731〉
  • H. Liebgott. Echantillonnage compressé pour l'imagerie ultrasonore médicale. Journée du GDR ISIS: Capteurs d'images pour le TDSI, Sep 2012, Grenoble, France. 〈hal-00831311〉
  • H. Liebgott, A. Basarab, D. Kouame, Olivier Bernard, D. Friboulet. Echantillonnage compressé pour l'imagerie ultrasonore médicale. Journée GDR ISIS - GDR Stic-Santé : Représentations parcimonieuses, échantillonnage compressé et imagerie médicale, Nov 2012, Paris, France. 〈hal-00831314〉
  • B. Diarra, H. Liebgott, C. Cachard, P. Tortoli. Non-grid based elements positioning for optimal 2D array beams. IEEE International Ultrasonics Symposium 2012, Oct 2012, Dresden, Germany. 〈hal-00830790〉
  • B. Diarra, H. Liebgott, M. Robini, P. Tortoli, C. Cachard. Optimized 2-D array design for ultrasound imaging. 20th European Signal Processing Conference (Eusipco), Aug 2012, Bucarest, Romania. pp.2718 - 2722, 2012. 〈hal-00830916〉
  • M. Alessandrini, H. Liebgott, D. Friboulet, O. Bernard. Monogenic phase based myocardium motion analysis from cardiac ultrasound with transverse oscillations. IEEE International Ultrasonic Symposium (IUS), 2012, Dresden, Germany. pp.1098-1101, 2012. 〈hal-01955144〉
  • S. Salles, G. Zahnd, H. Liebgott, A. Sérusclat, D. Vray. Estimation 2D du mouvement de la paroi carotidienne sur des séquences d'images US RF tagguées. Nouvelles méthodologies en imagerie du vivant, Dec 2012, Lyon, France. 〈hal-00829538〉
  • Y. Zhao, H. Liebgott, C. Cachard. Tracking micro tool in a dynamic 3D ultrasound situation using Kalman filter and RANSAC algorithm. IEEE International Symposium on Biomedical Imaging - ISBI2012, May 2012, Barcelona, Spain. pp.1076-1079, 2012, 〈10.1109/ISBI.2012.6235745〉. 〈hal-00830289〉
  • X. Guo, D. Friboulet, H. Liebgott. Transverse oscillations beamformer design for sector scan using back-propagation. IEEE International Symposium on Biomedical Imaging - ISBI2012, May 2012, Barcelona, Spain. pp.1100-1103, 2012, 〈10.1109/ISBI.2012.6235751〉. 〈hal-00830300〉
  • O. Lorintiu, Olivier Bernard, D. Friboulet, H. Liebgott. Imagerie ultrasonore médicale par échantillonnage compressés. Nouvelles méthodologies en imagerie du vivant, Dec 2012, Lyon, France. 〈hal-00828870〉
  • F. Varray, Olivier Basset, C. Cachard, H. Liebgott. Multi resolution transverse oscillations for motion estimation in ultrasound images. IEEE International Symposium on Biomedical Imaging - ISBI2012, May 2012, Barcelona, Spain. pp.1120-1123, 2012, 〈10.1109/ISBI.2012.6235756〉. 〈hal-00830304〉
  • S. Salles, G. Zahnd, H. Liebgott, D. Vray. Real time US-tagging combined with phase-based optical flow applied to 2D motion estimation of the carotid artery wall. IEEE International Ultrasonics Symposium 2012, Oct 2012, Dresden, Germany. 〈hal-00840399〉
  • Xinxin Guo, Denis Friboulet, Hervé Liebgott. Back-propagation based beamformer design for Transverse Oscillations in Echocardiography. Société Française d'Acoustique. Acoustics 2012, Apr 2012, Nantes, France. 2012. 〈hal-00810784〉
  • Yue Zhao, Hervé Liebgott, Christian Cachard. Tracking biopsy needle using Kalman filter and RANSAC algorithm with 3D ultrasound. Société Française d'Acoustique. Acoustics 2012, Apr 2012, Nantes, France. Acoustics 2012 Nantes, 2012. 〈hal-00810785〉
  • Bakary Diarra, Hervé Liebgott, Piero Tortoli, Christian Cachard. Sparse array techniques for 2D array ultrasound imaging. Société Française d'Acoustique. Acoustics 2012, Apr 2012, Nantes, France. Acoustics 2012 Nantes, 2012. 〈hal-00810649〉
  • Martino Alessandrini, H. Liebgott, D. Friboulet, Olivier Bernard. Simulation of realistic echocardiographic sequences for ground-truth validation of motion estimation. IEEE International Conference on Image Processing (ICIP'12), Sep 2012, Orlando, United States. pp.2329 - 2332, 2012, 〈10.1109/ICIP.2012.6467363〉. 〈hal-00830363〉
  • B. Gibaud, G. Forestier, B. Benoit-Cattin, F. Cervenansky, P. Clarysse, et al.. Design of an ontology for the annotation of object models used for medical image simulation. Nouvelles méthodologies en imagerie du vivant, Dec 2012, Lyon, France. 〈hal-00829556〉
  • Martino Alessandrini, H. Liebgott, A. Basarab, P. Clarysse, Olivier Bernard. Monogenic signal for cardiac motion analysis from tagged magnetic resonance image sequences. Computing in Cardiology 2012, Sep 2012, Krakow, Poland. pp.685 - 688, 2012. 〈hal-00839229〉
  • T. Glatard, A. Marion, H. Benoit-Cattin, S. Camarasu-Pop, P. Clarysse, et al.. Multi-modality image simulation with the Virtual Imaging Platform: Illustration on cardiac echography and MRI. IEEE International Symposium on Biomedical Imaging - ISBI2012, May 2012, Barcelona, Spain. pp.98-101, 2012, 〈10.1109/ISBI.2012.6235493〉. 〈hal-00830243〉
  • B. Gibaud, G. Forestier, H. Benoit-Cattin, F. Cervenansky, P. Clarysse, et al.. OntoVIP: an ontology for the annotation of object models used for medical image simulation. IEEE International Conference on Healthcare Informatics, Imaging and Systems Biology (HISB), Sep 2012, La Jolla, United States. pp.110, 2012, 〈10.1109/HISB.2012.35〉. 〈hal-00830912〉
  • F. Douziech, H. Liebgott, O. Bernard, A. Basarab. Affine phase based motion estimation applied to echocardiography. IEEE International Ultrasonic Symposium, 2011, Orlando, USA, Unknown Region. pp.736-739, 2011, 〈10.1109/ULTSYM.2011.0179〉. 〈hal-01955145〉
  • B. Diarra, H. Liebgott, P. Tortoli, C. Cachard. 2D matrix array optimization by simulated annealing for 3D hepatic imaging. IEEE International Ultrasonics Symposium, 2011, Orlando, Florida,USA, Unknown Region. pp.1595-1598, 2011, 〈10.1109/ULTSYM.2011.0396〉. 〈hal-01955146〉
  • D. Friboulet, H. Liebgott, R. Prost. Reconstruction de données RF ultrasonores par compressive sensing. GRETSI, 2011, Bordeaux, France. 2011. 〈hal-01922166〉
  • J. Richy, H. Liebgott, R. Prost, D. Friboulet. Blood Velocity Estimation Using Compressed Sensing. IEEE International Ultrasonics Symposium, 2011, Orlando (USA), Unknown Region. pp.1427-1430, 2011, 〈10.1109/ULTSYM.2011.0353〉. 〈hal-01922168〉
  • G. Forestier, A. Marion, H. Benoit-Cattin, P. Clarysse, D. Friboulet, et al.. Sharing object models for multi-modality medical image simulation: a semantic approach. The 24th International Symposium on Computer-Based Medical Systems (CBMS 2011), 2011, Bristol, UK, Unknown Region. pp.1-6, 2011, 〈10.1109/CBMS.2011.5999167〉. 〈hal-01922171〉
  • A. Marion, G. Forestier, H. Benoit-Cattin, Sorina Camarasu-Pop, P. Clarysse, et al.. Multi-modality medical image simulation of biological models with the Virtual Imaging Platform (VIP). The 24th International Symposium on Computer-Based Medical Systems (CBMS 2011), 2011, Bristol, UK, Unknown Region. pp.1-6, 2011, 〈10.1109/CBMS.2011.5999141〉. 〈hal-01922169〉
  • P. Gueth, R. Blanchard, H. Liebgott, O. Basset. Improved resolution for ultrasound Fourier imaging. IEEE International Ultrasonic Symposium, 2010, San Diego, USA, Unknown Region. pp.1735-1738, 2010, 〈10.1109/ULTSYM.2010.5935714〉. 〈hal-01955148〉
  • H. Liebgott. Fourier domain beamforming for transverse oscillations. IEEE International Ultrasonic Symposium, 2010, San Diego, USA, Unknown Region. IEEE, pp.1755 - 1758, 2010, 〈10.1109/ULTSYM.2010.5935762〉. 〈hal-01955150〉
  • D. Friboulet, H. Liebgott, R. Prost. Compressive sensing for raw RF signals reconstruction in ultrasound. IEEE International Ultrasonics Symposium, 2010, San Diego, California, USA, Unknown Region. pp.367-370, 2010, 〈10.1109/ULTSYM.2010.5935766〉. 〈hal-01922175〉
  • H. Liebgott, A. Basarab, P. Gueth, D. Friboulet, Philippe Delachartre. Transverse oscillations for tissue motion estimation. International Congress on Ultrasonics 2009, Physics Procedia, 2010, Santiago, Chile. 3, pp.235-244, 2010, 〈10.1016/j.phpro.2010.01.032〉. 〈hal-01923301〉
  • P. Gueth, Philippe Delachartre, H. Liebgott. Motion estimation using prebeamformed ultrasound signals. IEEE International Ultrasonic Symposium, 2010, San Diego, USA, Unknown Region. pp.2004-2007, 2010, 〈10.1109/ULTSYM.2010.5935717〉. 〈hal-01955147〉
  • M. Uhercik, H. Liebgott, J. Kybic, C. Cachard. Needle localization methods in 3D ultrasound data. International Congress on Ultrasonics, 2009, Santiago, Chile. 2009. 〈hal-01955153〉
  • M. Uhercik, J. Kybic, C. Cachard, H. Liebgott. Line Filtering for Detection of Microtools in 3D Ultrasound Data. IEEE International Ultrasonics Symposium, 2009, Roma, Italia, Unknown Region. pp.594-597, 2009, 〈10.1109/ULTSYM.2009.5441538〉. 〈hal-01955154〉
  • H. Liebgott, A. Ben Salem, A. Basarab, H. Gao, P. Claus, et al.. Tangential sound field oscillations for 2D motion estimation in echocardiography. IEEE International Ultrasonics Symposium, 2009, Roma, Italy. pp.498-501, 2009, 〈10.1109/ULTSYM.2009.5441917〉. 〈hal-01922366〉
  • D. Grenier, E. Brusseau, H. Liebgott, F. Duboeuf, F. Pilleul, et al.. MR-Elastography versus quasi-static US-Elastography. ESMRMB, 2009, Antalya, Turkey. pp.366, 2009. 〈hal-01955151〉
  • G. Zahnd, A. Basarab, H. Liebgott, O. Basset, Philippe Delachartre. Real-time specific beamforming applied to motion trajectory estimation in ultrasound imaging. IEEE International Ultrasonics Symposium, 2009, Roma, Italy. pp.1342-1345, 2009, 〈10.1109/ULTSYM.2009.5441925〉. 〈hal-01955155〉
  • P. Gueth, H. Liebgott, Philippe Delachartre. Formation de champ de déplacements à partir des signaux bruts. Application à l\'imagerie ultrasonore en synthèse d\'ouverture. XXIIe Colloque GRETSI - Traitement du Signal et des Images (GRETSI\textquoteright09), 2009, Dijon, France. pp.ID341, 2009. 〈hal-01955156〉
  • M. Uhercik, J. Kybic, H. Liebgott, C. Cachard. Multi-Resolution Parallel Integral Projection for Fast Localization of a Straight Electrode in 3D Ultrasound Images. IEEE International Symposium on Biomedical Imaging (ISBI), 2008, Paris, France. pp.33\textendash36, 2008, 〈10.1109/ISBI.2008.4540925〉. 〈hal-01955157〉
  • H. Liebgott, A. Basarab, S. Marincas, O. Bernard, D. Friboulet. Tangential oscillations for motion estimation in echocardiography. IEEE International Ultrasonics Symposium, 2008, Beijing, China. pp.1761-1764, 2008. 〈hal-01922367〉
  • J.M. Mari, H. Liebgott, C. Cachard. Ultrasonic scanning of micro needle in biological tissues. International Congress on Ultrasonics, 2007, Vienna, Austria. 2007, 〈10.3728/ICUltrasonics.2007.Vienna.1556_mari〉. 〈hal-01955162〉
  • H. Liebgott, Olivier Bernard, C. Cachard, D. Friboulet. Field simulation parameters design for realistic statistical parameters of Radio-Frequency ultrasound images. IEEE International Ultrasonics Symposium, 2007, New-York, USA, Unknown Region. pp.2247-2250, 2007, 〈10.1109/ULTSYM.2007.565〉. 〈hal-01922375〉
  • F. Duboeuf, H. Liebgott, A. Basarab, E. Brusseau, Philippe Delachartre, et al.. Static mechanical assessment of elastic Young\textquoterights modulus of tissue mimicking materials used for medical imaging. Proc. 29th Int. IEEE EMBC 2007, 2007, Lyon, France. pp.3450-3453, 2007, 〈10.1109/IEMBS.2007.4353073〉. 〈hal-01955163〉
  • A. Basarab, P. Gueth, H. Liebgott, Philippe Delachartre. Two-dimensional least-squares estimation for motion tracking in ultrasound elastography. IEEE EMBC, 2007, Lyon, France. pp.2155-2158, 2007, 〈10.1109/IEMBS.2007.4352749〉. 〈hal-01955159〉
  • A. Basarab, W. Aoudi, H. Liebgott, D. Vray, Philippe Delachartre. Parametric deformable block matching for ultrasound imaging. IEEE International Conference on Image Processing ICIP\textquoteright07, 2007, San Antonio, USA, Unknown Region. pp.II-429-II-432, 2007, 〈10.1109/ICIP.2007.4379184〉. 〈hal-01955160〉
  • P. Gueth, A. Basarab, H. Liebgott, Philippe Delachartre. Beamforming techniques for motion estimation in ultrasound elastography. IEEE International Ultrasonics Symposium, 2007, New-York, USA, Unknown Region. pp.1953-1956, 2007, 〈10.1109/ULTSYM.2007.491〉. 〈hal-01955158〉
  • M. Barva, J. Kybic, H. Liebgott, V. Hlavac, C. Cachard. Comparison of Methods for Tool Localization in Biological Tissue from 3D Ultrasound Data. IEEE International Ultrasonics Symposium, 2006, Vancouver, Canada. pp.1883-1886, 2006, 〈10.1109/ULTSYM.2006.507〉. 〈hal-01955166〉
  • A. Basarab, H. Liebgott, C. Grava, Philippe Delachartre. Two-dimensional sub-sample estimation using plane phase fitting. IEEE ICASSP, 2006, Toulouse, France. 2, pp.1152-1155, 2006, 〈10.1109/ICASSP.2006.1660552〉. 〈hal-01955165〉
  • H. Liebgott, A. Basarab, D. Loizeau, J.E. Wilhjelm, J.A. Jensen, et al.. Improved Beamforming for Lateral Oscillations in Elastography Using Synthetic Aperture Imaging. IEEE International Ultrasonics Symposium, 2006, Vancouver, Canada. pp.(2168-2171), 2006, 〈10.1109/ULTSYM.2006.548〉. 〈hal-01955164〉
  • W. Aoudi, H. Liebgott, A. Needles, V. Yang, S. Foster, et al.. Estimation 3D du flux sanguin par Imagerie Ultrasonore Haute Fréquence: Application à l\textquoterightétude de la microcirculation. GRETSI\textquoteright05, 2005, Louvain-La-Neuve, Belgium. pp.363-366, 2005. 〈hal-01955168〉
  • G. Said, D. Vray, H. Liebgott, J. Fromageau, E. Brusseau, et al.. Young modulus imaging based on axial and lateral strain estimation using a standard linear probe. SPIE Medical Imaging, 2005, San Diego, USA, Unknown Region. 5750, pp.397-404, 2005, 〈10.1117/12.590385〉. 〈hal-01955169〉
  • H. Liebgott, J. Fromageau, J.E. Wilhjelm, D. Vray, Philippe Delachartre. Direct estimation of the lateral strain field using a double oscillating point spread function with a scaling factor estimator. SPIE Medical Imaging, 2004, San Diego, USA, Unknown Region. 5 (27), pp.163-172, 2004, 〈10.1117/12.533023〉. 〈hal-01955170〉
  • Philippe Delachartre, H. Liebgott, S. Michelet, M. Pernot, D. Vray. Hardware implementation for receive beamforming and transverse elasticity imaging. IEEE International Ultrasonics Symposium, 2004, Montréal, Canada. pp.1488-1491, 2004, 〈10.1109/ULTSYM.2004.1418084〉. 〈hal-01955171〉
  • A. Jarrot, H. Liebgott, Philippe Delachartre, M. Robini. Edge-Preserving reconstruction for Young\textquoterights modulus recovery from ultrasonic data. IEEE Ultrasonics Symposium, 2003, Honolulu, Hawaii, USA, Unknown Region. pp.1919-1922, 2003, 〈10.1109/ULTSYM.2003.1293291〉. 〈hal-01955172〉
  • J. Fromageau, H. Liebgott, E. Brusseau, G. Gimenez, Philippe Delachartre, et al.. Correction of stress decay in intravascular elastography by combination of radial and tangential strain. IEEE International Ultrasonics Symposium, 2002, Munich, Germany. pp.1877-1880, 2002, 〈10.1109/ULTSYM.2002.1192675〉. 〈hal-01955173〉

Poster5 documents

  • Roux Emmanuel, Francois Varray, Lorena Petrusca, Christian Cachard, Piero Tortoli, et al.. 3D Diverging Waves with 2D Sparse Arrays: A Feasibility Study. 2017 IEEE International Ultrasonic Symposium (IUS), Sep 2017, Washington, United States. 2017. 〈hal-01599702〉
  • Vincent Perrot, Lorena Petrusca, Adeline Bernard, Didier Vray, Hervé Liebgott. Simultaneous Pulse Wave and Flow Estimation at High-Framerate Using Plane Waves and Transverse Oscillations on a Carotid Phantom. 2017 IEEE International Ultrasonic Symposium (IUS), Sep 2017, Washington, United States. 2017. 〈hal-01609228〉
  • Emeline Turquin, François Varray, Lorena Petrusca, Magalie Viallon, Hervé Liebgott. 3D Ultrasound Imaging of Tissue Anisotropy Using Spatial Coherence: Comparison between Plane Waves and Diverging Waves. 2017 IEEE International Ultrasonic Symposium (IUS), Sep 2017, Washington, United States. 2017. 〈hal-01599497〉
  • Maxime Polichetti, Francois Varray, Christian Cachard, Barbara Nicolas, Hervé Liebgott. IMAGERIE HARMONIQUE ULTRASONORE PAR INVERSION D’IMPULSION A HAUTE CADENCE D’IMAGERIE. Recherche en Imagerie et Technologies pour la Santé (RITS) 2017, Mar 2017, Lyon, France. 〈hal-01505475〉
  • Vincent Perrot, Selina Meier, Aline Bel-Brunon, Hélène Walter-Le Berre, Benyebka Bousaïd, et al.. Montage expérimental biofidèle d'aorte abdominale. Recherche en Imagerie et Technologies pour la Santé (RITS) 2017, Mar 2017, Lyon, France. 〈hal-01505250〉

Chapitre d'ouvrage2 documents

  • D. Vray, E. Brusseau, V. Detti, F. Varray, A. Basarab, et al.. Ultrasound Medical Imaging. Medical Imaging Based on Magnetic Fields and Ultrasounds, John Wiley & Sons, Inc., pp.1-72, 2014, 〈10.1002/9781118761236.ch1〉. 〈hal-00976667〉
  • D. Vray, E. Brusseau, V. Detti, F. Varray, A. Basarab, et al.. Imagerie médicale ultrasonore. BRIGUET André, FANET Hervé, SAPPEY-MARINIER Dominique, VRAY Didier. Imagerie médicale à base de champs magnétiques et d'ultrasons, Hermes-Lavoisier, pp.NA, 2014, Traité EGEM, série Electronique et micro-électronique. 〈hal-00976660〉

Direction d'ouvrage, Proceedings, Dossier1 document

  • B Presles, M Fargier-Voiron, M. Alessandrini, M.-C Biston, P Pommier, et al.. Realistic Simulations for the Evaluation of Monomodal Registration Algorithms of 3D Pelvic Ultrasound Images. Nico F. Declercq. 2015 ICU International Congress on Ultrasonics, May 2015, Metz, France. 70, Elsevier, pp.1169-1172, 2015, Physics Procedia: Proceedings of the 2015 ICU International Congress on Ultrasonics, Metz, France, 〈10.1016/j.phpro.2015.08.251〉. 〈hal-01265785〉