Researcher identifiers

Export Publications

Export the displayed publications:
Number of documents

21

Dominique CERTON


A venir


Journal articles14 documents

  • Jacques Heller, Audren Boulme, Daniel Alquier, Sophie Ngo, Dominique Certon. Performance Evaluation of CMUT-Based Ultrasonic Transformers for Galvanic Isolation. IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control, Institute of Electrical and Electronics Engineers, 2018, 65 (4), pp.617-629. ⟨10.1109/TUFFC.2018.2796303⟩. ⟨hal-02123675⟩
  • Dominique Gross, Mathieu Legros, Philippe Vince, Dominique Certon. Evaluation of an Ultrasound-Guided Focused Ultrasound CMUT Probe for Targeted Therapy Applications. Open Journal of Applied Sciences, Scientific Research Publishing, 2018, 08 (01), pp.25 - 45. ⟨10.4236/ojapps.2018.81003⟩. ⟨hal-01862175⟩
  • J. Lascaud, Thomas Defforge, Dominique Certon, D. Valente, Gaël Gautier. In-depth porosity control of mesoporous silicon layers by an anodization current adjustment. Journal of Applied Physics, American Institute of Physics, 2017, 122 (21), ⟨10.1063/1.4997228⟩. ⟨hal-01741078⟩
  • Tomasz Zawada, Louise Moller Bierregaard, Erling Ringgaard, Ruichao Xu, Michele Guizzetti, et al.. Characterization of Kerfless Linear Arrays Based on PZT Thick Film. IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control, Institute of Electrical and Electronics Engineers, 2017, 64 (9), pp.1409 - 1416. ⟨10.1109/TUFFC.2017.2709253⟩. ⟨hal-01740978⟩
  • Emilie Bahette, Jean-François Michaud, Dominique Certon, Dominique Gross, Marie Perroteau, et al.. Low temperature capacitive micromachined ultrasonic transducers (cMUTs) on glass substrate. Journal of Micromechanics and Microengineering, IOP Publishing, 2016, 26 (11), ⟨10.1088/0960-1317/26/11/115023⟩. ⟨hal-01741067⟩
  • Dominique Gross, C. Coutier, M. Legros, Ayache Bouakaz, Dominique Certon. A cMUT Probe for Ultrasound-Guided Focused Ultrasound Targeted Therapy. IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control, Institute of Electrical and Electronics Engineers, 2015, 62 (6), pp.1145-1160. ⟨10.1109/TUFFC.2014.006887⟩. ⟨hal-01814875⟩
  • Audren Boulmé, Dominique Certon. Design of Broadband Linear Micromachined Ultrasonic Transducer Arrays by Means of Boundary Element Method Coupled with Normal Mode Theory. IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control, Institute of Electrical and Electronics Engineers, 2015, 62 (9), pp.1704-1716. ⟨10.1109/TUFFC.2015.006986⟩. ⟨hal-01814874⟩
  • Audren Boulmé, Sophie Ngo, Jean-Gabriel Minonzio, Mathieu Legros, Maryline Talmant, et al.. A capacitive micromachined ultrasonic transducer probe for assessment of cortical bone. IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control, Institute of Electrical and Electronics Engineers, 2014, 61 (4), pp.710-723. ⟨10.1109/TUFFC.2014.2959⟩. ⟨hal-01302015⟩
  • Emilie Bahette, Jean-François Michaud, Dominique Certon, Dominique Gross, Daniel Alquier. Progresses in cMUT Device Fabrication Using Low Temperature Processes. Journal of Micromechanics and Microengineering, IOP Publishing, 2014, 24 (4), pp.045020. ⟨hal-01831020⟩
  • Sébastien Ménigot, Dominique Certon, Dominique Gross, Jean-Marc Girault. Automatic Optimal Input Command for Linearization of cMUT Output by a Temporal Target. IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control, Institute of Electrical and Electronics Engineers, 2014, 61 (10), pp.1742--1753. ⟨10.1109/TUFFC.2013.006330⟩. ⟨hal-01069932⟩
  • Nicolas Sénégond, Audren Boulmé, Camille Plag, Franck Teston, Dominique Certon. Fast Time-Domain Modeling of Fluid-Coupled cMUT Cells: From the Single Cell to the 1-D Linear Array Element. IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control, Institute of Electrical and Electronics Engineers, 2013, 60 (7), pp.1505-1518. ⟨10.1109/TUFFC.2013.2723⟩. ⟨hal-01814882⟩
  • Dominique Certon, R. Ternifi, Audren Boulmé, M. Legros, J.-G. Minonzio, et al.. Low Frequency cMUT Technology: Application to Measurement of Brain Movement and Assessment of Bone Quality. IRBM, Elsevier Masson, 2013, 34 (2), pp.159-166. ⟨10.1016/j.irbm.2013.01.009⟩. ⟨hal-01814883⟩
  • A. Bouakaz, G. Ferin, Dominique Certon, O. Basset. Imagerie ultrasonore de contraste avec transducteurs capacitifs micro-usinés. IRBM, Elsevier Masson, 2011, 32, pp.102\textendash105. ⟨hal-01986414⟩
  • L. Tessier, M. Lethiecq, D. Certon, F. Patat. Impédance acoustique d'un liquide à la surface d'un quartz coupe AT. Journal de Physique IV Colloque, 1994, 04 (C5), pp.C5-1205-C5-1208. ⟨10.1051/jp4:19945266⟩. ⟨jpa-00252956⟩

Conference papers7 documents

  • Luis Iglesias, Priyadarshini Shanmugam, Steven Pena, Jean-François Michaud, Daniel Alquier, et al.. Time of flight gas sensing with capacitive micro-machined ultrasonic transducers (CMUT’s). Journées de l’école doctorale SPI Université de Bordeaux, Mar 2019, Bordeaux, France. ⟨hal-02090954⟩
  • Priyadarshini Shanmugam, Luis Iglesias, Jean-François Michaud, Isabelle Dufour, Daniel Alquier, et al.. CMUT Based Air Coupled Transducers for Gas-Mixture Analysis. 2018 IEEE International Ultrasonics Symposium (IUS), Oct 2018, Kobe, Japan. pp.1-4, ⟨10.1109/ULTSYM.2018.8579789⟩. ⟨hal-02013282⟩
  • Sébastien Ménigot, Dominique Certon, Dominique Gross, Jean Marc Girault. Automatic Optimal Command for the Linearization of the CMUT Output. MUT 2013, Jun 2013, Side, Turkey. ⟨hal-01459700⟩
  • Dominique Gross, Audren BoulmÉ, Nicolas Sénégond, Guillaume Férin, Mathieu Legros, et al.. Dual mode transducers based on cMUTs technology. Acoustics 2012, Apr 2012, Nantes, France. ⟨hal-00811242⟩
  • Audren BoulmÉ, Nicolas Sénégond, Franck Teston, Dominique Certon. A model to predict baffle effects in linear array of cMUTs. Acoustics 2012, Apr 2012, Nantes, France. ⟨hal-00811294⟩
  • Audren Boulme, Dominique Certon, Cyril Meynier, Nicolas Sénégond, Franck Teston. Modélisation d'une barrette de cMUTs par une approche multi-échelle. 10ème Congrès Français d'Acoustique, Apr 2010, Lyon, France. ⟨hal-00550894⟩
  • Nicolas Sénégond, Franck Teston, Jean-Edouard Bernard, Dominique Certon. Réponse non linéaire d'une population de cMUTs : modèle et mesure. 10ème Congrès Français d'Acoustique, Apr 2010, Lyon, France. ⟨hal-00551190⟩