Christophe DOLABDJIAN
104
Documents
Publications
Magnetic Properties of Co-Fe-Si-B MicrowiresSMMM'2016, Oct 2016, Czestochowa, France. pp.1256 - 1259, ⟨10.12693/APhysPolA.131.1256⟩
Communication dans un congrès
hal-01633296v1
|
|
Experimental and Analytical investigation of Magnetic Imaging using Magnetic NanoparticlesProc. of EMSA, 2014, vienne, France
Communication dans un congrès
hal-00982146v1
|
|
|
Low frequency excess noise source investigation of off-diagonal GMI-based magnetometersEuropean Magnetic Sensors and Actuators Conference 2014, Jul 2014, Vienne, Austria
Communication dans un congrès
hal-01109729v1
|
|
Noise behavior of high sensitive GMI-based magnetometer relative to conditioning parameters10th European Conference on Magnetic Sensors and Actuators (EMSA 14), Jul 2014, Vienne, Austria. 4 p., ⟨10.1109/TMAG.2014.2355414⟩
Communication dans un congrès
hal-01061135v1
|
|
Is low frequency excess noise of GMI induced by magnetization fluctuations ?International Conference on Materials and Applications for Sensors and Transducers (ICMAST), 2013, prague, Czech Republic
Communication dans un congrès
hal-00988089v1
|
|
Magnetic sensor noise impact on the evaluation of magnetorelaxometry experimentsInternational Conference on Noise and Fluctuations (ICNF), 2013, Montpellier, France
Communication dans un congrès
hal-00981597v1
|
Noise and sensitivity of GMI sensing elementsEuropean Magnetic Sensors and Actuators Conference 2012, Jul 2012, Prague, Czech Republic
Communication dans un congrès
hal-01109721v1
|
|
|
Microfluidic microsystem for magnetic sensing of nanoparticles with giant magneto-impedance technology16th International Conference on Solid-State Sensors, Actuators and Microsystems, TRANSDUCERS'11, 2011, Beijing, China. pp.80-83, ⟨10.1109/TRANSDUCERS.2011.5969140⟩
Communication dans un congrès
hal-00800386v1
|
GMI Noise performance optimisationMagnetic Measurement Conference 2010, Sep 2010, Prague, Czech Republic
Communication dans un congrès
hal-01109718v1
|
|
Magnetometre à tres haute sensibilité pour le contrôle non destructif pa courant de FoucaultColloque interdisciplinaire en instrumentation (C2I), 2010, France
Communication dans un congrès
hal-00987176v1
|
|
|
Etat de l'art du développement des contrôles non destructifs par des méthodes électromagnétiques à l'aide de magnétomètre à haute sensibilitéThe e-Journal \& Database of Nondestructive Testing (NDT.net), 2009, France
Communication dans un congrès
hal-00987188v1
|
|
Modeling and fabrication of piezoelectric aluminium nitride resonator and its application in oscillatorsSolid-State Sensors, Actuators and Microsystems Conference, 2009, Denver, United States. pp.565-568, ⟨10.1109/SENSOR.2009.5285387⟩
Communication dans un congrès
hal-00989687v1
|
|
Piezoelectric aluminum nitride resonator for oscillatorFrequency Control Symposium, 2009 Joint with the 22nd European Frequency and Time forum. IEEE International, Apr 2009, Besançon, France. p894-897
Communication dans un congrès
hal-00994757v1
|
Analysis of the intrinsic field sensitivity and noise of magnetoimpedance sensorsInternational Magnetics Conference, Apr 2008, Madrid, Spain
Communication dans un congrès
hal-01109795v1
|
|
Detection of cell internalized maghemite nanoparticles with a GMI biosensorEMSA'08, Caen France, 2008, 2008, Caen, France. pp 1-9
Communication dans un congrès
hal-00986484v1
|
|
MAGNETIC NOISE COMPARAISON IN GMI BASED SENSING DEVICESConférence internationale EMSA'06, 2006, Bilbao, Spain
Communication dans un congrès
hal-00023646v1
|
|
Intrinsic GMI noise reduction by DC BIASConférence internationale EMSA'06, 2006, BILBAO, Spain
Communication dans un congrès
hal-00023644v1
|
|
Improvement in subsurface fatigue cracks under airfames fasteners detection using improved rotating Giant Magneto-Resistance Magnetometer headECND'06, 2006, Berlin, Germany
Communication dans un congrès
hal-00013583v1
|
|
Towards material characterization and thickness measurements using Pulsed Eddy Currents implemented with an Improved Giant MagnetoResistance MagnetometerECNDT'06, 2006, Berlin, Germany
Communication dans un congrès
hal-00013584v1
|
|
LOW FREQUENCY GMI MAGNETOMETER NOISE VERSUS ELECTRONICS CONDITIONINGConférence internationale EMSA'06, 2006, BILBAO, Spain
Communication dans un congrès
hal-00023645v1
|
|
Comparaison d'un filtrage numérique à l'aide de la transformée d'ondelettes discrète, mis en oeuvre en temps réel sur un DSP, à un filtrage classique de type P-BColloque interdisciplinaire en instrumentation, C2I 2001, Jan 2001, Paris, France. pp.397-404
Communication dans un congrès
hal-01107288v1
|
|
Sensitivity performance of magnetic field sensor based on magnonic crystalsEuropean Magnetic Sensors and Actuators (EMSA) Conference 2018, Jul 2018, Athens, France
Poster de conférence
hal-03716349v1
|
Impact of physico-chemical treatments on the low frequency noise of GMI-based magnetometersEuropean Magnetic Sensors and Actuators Conference 2014, Jul 2014, Vienne, Austria
Poster de conférence
hal-01109731v1
|
|
|
Optimized off-diagonal GMI-based magnetometerMagnetic Scholl : High sensitivity magnetometers, Oct 2012, Branville, France. 2012
Poster de conférence
hal-01109723v1
|
|
Study of an hybrid mangetometer : YIGMagnetic School : High sensitivity magnetometers - Sensors and Applications 2007, Sep 2007, Blainville-sur-mer, France
Poster de conférence
hal-01109733v1
|
Sensors Letters : A Special Issue on The European Magnetic Sensors and Actuators Conference, EMSA'08American Scientific Publishers, pp.298, 2009
Ouvrages
hal-00982976v1
|
Giant Magneto-Impedance (GMI) Magnetometers Smart Sensors, Measurement and Instrumentation book series (SSMI, volume 19), 2016
Chapitre d'ouvrage
hal-01633299v1
|
Device for measuring a magnetic field, associated system and methodFrance, Patent n° : 20290004.9 - 1010. 2020
Brevet
hal-02965850v1
|
|
Method for determining physical characteristics of nanoparticles or agglomerates of nanoparticles, involves determining characteristics to minimize discrepancies between Fourier transforms of measured magnetism and predetermined magnetismFrance, Patent n° : WO2012022885-A1. 2012
Brevet
hal-00980257v1
|
|
Procédé et dispositif de détermination et dispositif de caractérisation physiques d'une fissure dans une pièce de matériau conducteur et système de surveillance structurelle correspondantFrance, N° de brevet: FR10/51718. 2010
Brevet
hal-00987173v1
|
|
Système de caractérisation de nano-particules magnétiquesFrance, Patent n° : FR10/56112. 2010
Brevet
hal-00995112v1
|
|
Mesure de la partie imaginaire de la susceptibilité magnétique de capteurs MIG - Application à l'évaluation de leur bruit en 1/f2016
Pré-publication, Document de travail
hal-01397063v1
|
|
Stress tunable magnetoelectric bending resonance for sensing static magnetic field2015
Pré-publication, Document de travail
hal-01162308v1
|